Weijs et al. (2023) · Royal Society Open Science
- Method
- Mixed-design VR experiment; hue between subjects, lightness/saturation within subjects; linear mixed models and Tukey-adjusted follow-up tests.
- Participants / setting
- 64 recruited; 60 retained after initial exclusions. Outcome-specific analyses included 57 for ECG, 46 for EDA and 59 for self-report. Mean age of retained sample: 27.6 years (SD 10.7).
- Study focus
- Tests red/blue virtual walls while varying lightness and saturation.
- Finding used
- Darker versus medium-lightness VR rooms differed in baseline-adjusted heart rate and HRV; neither condition differed significantly from baseline alone. Skin-conductance contrasts depended on hue and lightness/saturation. Self-reported valence and arousal did not differ.
- Architectural relevance
- Evaluate hue with lightness, saturation and user reports; no palette guarantees relaxation.
- Study-specific quantitative result
- Color: Heart-rate change from baseline Low versus medium lightness, across red and blue hues 64 recruited; 60 retained after initial exclusions; ECG analyses included 57 (EDA 46; self-report 59). 3-minute VR room-exploration segments following a 3-minute resting baseline Mean HR change: +0.24 bpm in low lightness versus −0.49 bpm in medium lightness; lightness F(1,164) = 6.35, p = .013. Uncertainty: Condition-mean 95% CIs: −0.77 to 1.26 and −1.50 to 0.53 bpm, respectively; these are not CIs for the paired contrast. Neither condition differed significantly from baseline. Analysis: Outcome hierarchy not specified in the material checked. Small physiological differences do not show a universal mood benefit; self-reported valence and arousal did not differ by color. The study was not preregistered. Material checked: Full text §§2.7.1–2.7.4 and 3.3.1 inspected; no formal outcome hierarchy declared. Non-preregistration is explicitly stated, not inferred.
- Interpretation limits
- Brief virtual exposure; condition-mean CIs are not paired-contrast CIs. Authors explicitly state that study design and analyses were not preregistered.
- Verification status
- Full paper · relevant sections checked
- Sections checked
- §2.7.1 outcome-specific exclusions · §2.7.3 statistical analyses · §2.7.4 transparency · §3.3.1 heart-rate/HRV results
- Unresolved / verification limits
- Formal primary/secondary outcome hierarchy not declared in the inspected Methods/Results.