Neuroenergetics

Fuel

Neural activity depends on energy supply, oxygen delivery and coordinated vascular and cellular processes. These biological requirements should be distinguished from the broader indoor-environment conditions associated with cognitive performance.

In architectural design

Specify and verify ventilation and pollutant control appropriate to occupancy and activities. Treat indoor carbon dioxide as contextual exposure information, and investigate contaminant sources rather than assuming fresh air directly fuels thought.

What we can say

The cited indoor-air studies did not establish cerebral oxygenation as a mediator. Carbon dioxide findings are mixed, and routine indoor concentrations do not imply oxygen deprivation.

Background perspective

Useful background for understanding people. This atlas does not establish a direct architectural intervention for this function.

Peer-reviewed sources & research audit1 background · 3 environmental papersOpen auditClose audit

Scientific background

These references support the definition and scientific context. Neuroscience and environmental-psychology frameworks are identified separately; they do not test the proposed architectural intervention.

01
Synaptic Energy Use and Supply

Harris, J. J., Jolivet, R., & Attwell, D. (2012). Neuron, 75(5), 762–777.

Foundational neuroscienceBackground only
Method
Peer-reviewed narrative review; no new architectural intervention
Participants / setting
Review of published research; no newly recruited architectural sample
Study focus
Review of energy consumption and supply in neural signaling.
Finding used
Explains the energetic costs of synaptic activity and processes supplying ATP to neurons.
Use in this page
Supports the general neuroscience definition only. It does not establish the proposed architectural effect.
Interpretation limits
Cellular energetics does not establish that ordinary indoor carbon dioxide causes cerebral oxygen deprivation or that ventilation effects are mediated by brain oxygenation.
Verification status
Full paper · relevant sections checked
Sections checked
Synaptic energy budget and Figure 2 · Regulating synaptic mitochondrial energy supply
Last checked 2026-10-10Publication status Peer-reviewedPrimary material · verification recordResearch audit / material checked Full paper available; relevant body sections checked for the atlas claim. · The review supports energy costs and metabolic supply, not oxygen deprivation caused by ordinary indoor CO₂ concentrations.

Environmental and architectural evidence

These papers support the environmental connection discussed here. Their findings do not prove the whole proposed biological explanation.

01
Direct experimentalModerate · atlas editorial assessment
Method
Blinded controlled office exposures · decision-making simulation
Participants / setting
24 participants, six full workdays
Study focus
Varies office VOCs, outdoor-air supply and added CO₂ across workdays.
Finding used
Decision scores were higher under low-VOC and enhanced-ventilation conditions.
Architectural relevance
Compare ventilation and low-emission specifications using measured exposure and task outcomes. Distinguish ventilation indicators from causal exposure claims; evaluate mixtures and relevant tasks.
Study-specific quantitative result
Ventilation & indoor emissions: Strategic Management Simulation cognitive scores Low-VOC Green and low-VOC/high-ventilation Green+ conditions versus Conventional conditions 24 participants in a blinded repeated-exposure experiment. Six full workdays (09:00–17:00) in a controlled office under differing ventilation, VOC and CO₂ conditions. Average SMS score ratio versus Conventional: Green 1.61 (95% CI 1.51–1.71); Green+ Day 1 1.99 (1.89–2.09); Green+ Day 6 2.03 (1.93–2.13); all p<.0001. The paper summarizes the two Green+ days as 101% higher. Uncertainty: Table 5 provides model-based CIs separately for Green+ days; it does not provide one pooled CI for the 101% summary. Simulation-score ratios are not percentage gains in productivity. Analysis: Outcome hierarchy not specified in the material checked. The condition comparison bundles aspects of air quality. It does not demonstrate a 101% productivity gain, an IQ gain, or that ordinary indoor CO₂ acts through oxygen deprivation. Material checked: Full paper: Statistical Analyses; Results; Table 5. Outcome hierarchy not declared in reviewed Methods/analysis; no preregistration inferred.
Interpretation limits
Small sample and one decision simulation; large relative test-score differences are not equivalent to productivity gains.
Verification status
Full paper · relevant sections checked
Sections checked
Statistical Analyses; Results; Table 5
Last checked 2026-10-10Publication status Peer-reviewedPrimary material · verification recordResearch audit / material checked Targeted full-text verification; not a formal risk-of-bias assessment. · Full-text Methods and Results checked
02
Direct experimentalLimited · atlas editorial assessment
Method
Blinded, balanced repeated chamber exposures; mixed ANOVA with Tukey HSD comparisons; cognitive tasks and self-ratings
Participants / setting
25 Danish students (10 men, 15 women), mean age 23 (SD 2), each completing five 255-minute exposures.
Study focus
Separates added pure CO₂ from accumulated occupant bioeffluents.
Finding used
Pure CO₂ showed no significant cognitive or symptom effects. Bioeffluent effects were mixed: slower addition and fewer correct links, but faster redirection in selected contrasts. Authors explicitly describe the analysis as exploratory.
Architectural relevance
Distinguish ventilation indicators from causal exposure claims; evaluate mixtures and relevant tasks.
Study-specific quantitative result
CO₂ & occupant bioeffluents: Cognitive-task performance and symptoms under CO₂ and human bioeffluent exposures Pure CO₂ addition versus reduced-ventilation human bioeffluents at comparable CO₂ concentrations 25 Danish students (10 men, 15 women), mean age 23 (SD 2), each completing five 255-minute exposures. Five 255-minute chamber exposures; approximately 500 ppm baseline, 1,000 or 3,000 ppm from pure CO₂ addition or reduced ventilation. Across conditions, addition speed differed (p=.023), as did addition errors (p=.049), redirection reaction time (p=.015), and correct Tsai–Partington links (p<.001). Bioeffluents at M3000 slowed addition versus B500, but redirection was faster versus P1000; correct links were lower at M1000 and M3000 versus B500. No pairwise addition-error contrast passed Tukey testing. Pure-CO₂ conditions showed no significant cognitive or symptom effects. Uncertainty: Omnibus p-values describe across-condition tests, not effect magnitudes or every pairwise contrast. Figure 6 supplies graphical means and 95% CIs; exact numeric limits remain unextracted because supplemental Tables S3–S5 returned 403. A nonsignificant pure-CO₂ result does not establish zero effect. Satish 2012 reports contrary task-specific findings. Analysis: exploratory CO₂ can mark inadequate ventilation and co-occurring human emissions. Do not attribute every association to CO₂ itself or claim an established cerebral oxygen-depletion mechanism at these concentrations. Material checked: Full accepted manuscript Methods, Results and Figure 6 reviewed. Authors explicitly call this analysis exploratory; this designation is not inferred from the number of outcomes.
Interpretation limits
Task-specific, exploratory results; not every bioeffluent task worsened. Graphical 95% CIs are reported; exact supplementary values remain inaccessible.
Verification status
Full paper · relevant sections checked
Sections checked
Accepted manuscript Methods; Statistical Analysis; Results; Figure 6 and exploratory-analysis statement
Unresolved / verification limits
Exact task means/contrasts and numeric confidence bounds: main Figure 6 gives graphical least-squares means and 95% CIs, but supporting Tables S3–S5 could not be downloaded (Wiley supplement URL and downloadSupplement endpoint both HTTP 403). No precise graph digitization performed.
Last checked 2026-10-10Publication status Peer-reviewedPrimary material · verification recordResearch audit / material checked Full accepted manuscript Methods, Results and Figure 6 reviewed. Authors explicitly call this analysis exploratory; this designation is not inferred from the number of outcomes. · Full-text methods and results checked
03
IndirectLimited · atlas editorial assessment
Method
12-month observational follow-up · Stroop/arithmetic tasks · indoor sensors
Participants / setting
302 office workers in six countries
Study focus
Links repeated office cognitive tests with contemporaneous indoor pollutant measurements.
Finding used
Higher PM₂.₅ and CO₂ were associated with slower or less accurate performance on several, but not all, metrics.
Architectural relevance
Include particle monitoring when comparing filtration and outdoor-air strategies.
Study-specific quantitative result
Indoor particulate matter: Repeated mobile Stroop task reaction time An interquartile-range increase of 8.8 µg/m³ in indoor PM₂.₅ 302 office workers in a longitudinal observational study. Office air monitoring and smartphone cognitive tests over 12 months in six countries. Stroop reaction time was 0.82% longer per PM₂.₅ interquartile increase; 95% CI 0.42% to 1.21%. Stroop throughput was 0.70% lower; 95% CI -1.38% to -0.01%. Uncertainty: Reported model-based confidence intervals quantify association uncertainty, not causal effects of installing filtration. Residual confounding and multiple task outcomes remain relevant. Analysis: Outcome hierarchy not specified in the material checked. A small task-specific association during office work; the study did not directly measure brain inflammation or establish a clinical outcome. Material checked: Full paper: Methods 2.4–2.5; adjusted-model Results; Figure 2. Outcome hierarchy not declared in reviewed Methods/analysis; no preregistration inferred.
Interpretation limits
Observational; pollutants and ventilation covary. The study does not test a filtration intervention or identify a neural mediator.
Verification status
Full paper · relevant sections checked
Sections checked
Methods 2.4–2.5; adjusted-model Results; Figure 2
Last checked 2026-10-10Publication status Peer-reviewedPrimary material · verification recordResearch audit / material checked Targeted full-text verification; not a formal risk-of-bias assessment. · Full-text Methods and Results checked