NeuroarchitectureDLA Visual AtlasVersion 1.0
DLA research workspace

Neuroscience & Space

Understand people before making a design decision.

45 functions · 6 themesOverlapping processes, explored through architecture.

How to read this page

Choose a theme, then a function. Read the design connection alongside its limits. These are research lenses, not separate brain regions or guaranteed effects of buildings. The link labels describe relevance; study quality and directness are assessed separately in the Evidence Atlas.

Neuroimmunology

Protect

Immune cells, vascular barriers and inflammatory signaling participate in nervous-system protection and disease. These mechanisms are biologically complex and cannot be inferred directly from a material label or room appearance.

In architectural design

Manage moisture, pollutant sources and appropriate ventilation or filtration using building-health guidance. Evaluate actual emissions and maintenance conditions; request suitable product evidence instead of treating a zero-VOC label as proof of safety.

What we can say

The atlas studies do not demonstrate that selected finishes prevent neuroinflammation. Diesel-exposure connectivity findings and building-symptom reviews do not establish a neuroimmune benefit from any particular product.

Background perspective

Useful background for understanding people. This atlas does not establish a direct architectural intervention for this function.

Peer-reviewed sources & research audit1 background · 2 environmental papersOpen auditClose audit

Scientific background

These references support the definition and scientific context. Neuroscience and environmental-psychology frameworks are identified separately; they do not test the proposed architectural intervention.

01
The movers and shapers in immune privilege of the CNS

Britta Engelhardt et al. (2017). Nature Immunology, 18(2), 123–131.

Foundational neuroscienceBackground only
Method
Peer-reviewed narrative review; no new architectural intervention
Participants / setting
Synthesis of published studies; no newly recruited architectural cohort
Study focus
Review of barriers and immune access in the central nervous system.
Finding used
Describes distinct endothelial, epithelial and glial interfaces, immune surveillance and routes of drainage.
Use in this page
Supports the background definition within the scope described here; it does not establish an architectural effect.
Interpretation limits
Does not show that a low-VOC label or any material specification prevents neuroinflammation; rodent and human anatomical differences matter.
Verification status
Full paper · relevant sections checked
Sections checked
Opening immune-privilege discussion (p. 123) · Acellular and cellular brain barriers · Conclusions and outlook (p. 129)
Last checked 2026-10-10Publication status Peer-reviewedPrimary material · verification recordResearch audit / material checked Research-group-hosted complete PDF read. · The full text distinguishes CNS compartments, immune surveillance and CSF versus interstitial drainage, and flags limits of imaging and animal models. The current background summary is supported.

Environmental and architectural evidence

These papers support the environmental connection discussed here. Their findings do not prove the whole proposed biological explanation.

01
Direct experimentalLimited · transfer to indoor particles
Method
Randomized blinded crossover · resting-state fMRI
Participants / setting
25 healthy adults, 19–49 years
Study focus
Compares two-hour diesel and filtered-air exposures, with light cycling.
Finding used
PCC-seeded connectivity was lower after diesel than filtered air; pre/post diesel alone was not significant.
Architectural relevance
Supplemental network evidence; PCC denotes analysis seed.
Interpretation limits
Diesel mixture at nominal 300 µg/m³ PM₂.₅ differs from ordinary offices. No isolated PCC injury or clinical benefit demonstrated.
Verification status
Earlier full-text extraction retained
02
Indirect · evidence synthesisLimited for isolated causal effects
Method
Literature review; 31 health/productivity studies plus environmental surveys
Participants / setting
Office workers across reviewed studies
Study focus
Reviews office air pollution, thermal, lighting and acoustic conditions and occupant outcomes.
Finding used
Environmental quality was associated with symptom complaints and work-related outcomes across heterogeneous studies.
Architectural relevance
Provides wider indoor-air-quality context for assessing ventilation and exposure mixtures; it does not resolve the conflicting pure-CO₂ experiments.
Interpretation limits
Exposure mixtures and mixed designs prevent a single causal pollutant or productivity effect from being inferred.
Verification status
Full paper · relevant sections checked
Sections checked
2. Method · 3.4.2 Effects of occupational exposure to inorganic air pollutants · 6.2 Effects of acoustical conditions on workers · 7. Conclusions and future trends
Last checked 2026-10-10Publication status Peer-reviewedPrimary material · verification recordResearch audit / material checked Relevant full-text body sections checked · Public author-uploaded body confirms the mixed literature on office environmental exposures and health/productivity outcomes, including inconsistent CO₂ results. The authors call for objective outcomes and investigation of interacting environmental factors. Findings do not justify single-pollutant causal or universal productivity claims.