NeuroarchitectureDLA Visual AtlasVersion 1.0
DLA research workspace

Evidence Atlas

Explore the relationships between architecture, experience and the body.

Body & evidence

Direct experimentalLimited evidence
About these labels

Relationship describes how the study connects to this architectural exposure. Confidence describes the support and limits for using that finding in design. A close match to a building or population does not by itself make the evidence strong.

Relationship

Direct experimentalSelected
The study manipulated an environmental feature or its representation. The finding applies to the tested exposure and participants.
Indirect
The architectural relationship uses an observational study, evidence synthesis or a transfer from another exposure or setting.
Theoretical inference
This relationship is a design or mechanistic hypothesis; the anchor does not establish a measured human benefit.

Confidence

Moderate evidence
A credible result within the tested conditions, with limits when transferred to another population, exposure or building.
Limited evidenceSelected
Confidence is restricted by factors such as a small sample, proxy measures, confounding or an uncertain transfer to architectural design.
Hypothesis
The proposed architectural relationship has no established measured human outcome in the anchor evidence.

These are atlas editorial assessments, not a formal GRADE assessment. A direct experiment can still provide limited evidence, and design recommendations remain interpretations of the findings.

CO₂ & occupant bioeffluents

Study exposure

Pure added CO₂ compared with reduced ventilation and accumulated human bioeffluents

Cognitive task performance

Measured with

Computerized response/decision tasks

Research finding

Zhang found no significant pure-CO₂ cognitive effect and mixed exploratory bioeffluent task effects; Satish found decrements on several decision scales.

Observation details & sources
Exposure

Pure added CO₂ compared with reduced ventilation and accumulated human bioeffluents

Measurement

Computerized response/decision tasks

Finding

Zhang found no significant pure-CO₂ cognitive effect and mixed exploratory bioeffluent task effects; Satish found decrements on several decision scales.

Interpretation

Behavioral outcomes do not locate a specific organ response.

Findings across linked studies

Zhang found no significant pure-CO₂ cognitive effect; exploratory bioeffluent contrasts included slower addition, fewer correct links and faster redirection. (Zhang et al. (2017)) Satish reported decrements on several decision scales. (Satish et al. (2012))

Design implication

Distinguish ventilation indicators from causal exposure claims; evaluate mixtures and relevant tasks.

Design proposal · Theoretical inferenceExplore design approaches →
Interpretation & limits

Small samples and different protocols; Zhang explicitly describes its analysis as exploratory and its task effects were mixed. No universal cognitive threshold follows.

CO₂ & occupant bioeffluents

Environmental comfort

Loading body model…

  • Inhalation
  • Bioeffluent odor
Spatial context

Related regions

Direct experimentalLimited evidence
About these labels

Relationship describes how the study connects to this architectural exposure. Confidence describes the support and limits for using that finding in design. A close match to a building or population does not by itself make the evidence strong.

Relationship

Direct experimentalSelected
The study manipulated an environmental feature or its representation. The finding applies to the tested exposure and participants.
Indirect
The architectural relationship uses an observational study, evidence synthesis or a transfer from another exposure or setting.
Theoretical inference
This relationship is a design or mechanistic hypothesis; the anchor does not establish a measured human benefit.

Confidence

Moderate evidence
A credible result within the tested conditions, with limits when transferred to another population, exposure or building.
Limited evidenceSelected
Confidence is restricted by factors such as a small sample, proxy measures, confounding or an uncertain transfer to architectural design.
Hypothesis
The proposed architectural relationship has no established measured human outcome in the anchor evidence.

These are atlas editorial assessments, not a formal GRADE assessment. A direct experiment can still provide limited evidence, and design recommendations remain interpretations of the findings.

Select a region for its finding and supporting source.

Explore design approaches →
Olfactory / piriform regionAnatomical pathway · indirectApproximate location only

Applies only to bioeffluent odor perception. Pure CO₂ is odorless; this marker does not explain CO₂-related task results.

No dedicated segmentation in the loaded atlas. The marker remains approximate; no exact location is claimed.

CO₂ & occupant bioeffluents

Environmental comfort

Loading anatomical surface…
  • Inhalation
  • Bioeffluent odor
Anterior = front · posterior = back
Peer-reviewed sources & research auditStudy details · 5 papersOpen auditClose audit

Peer-reviewed sources & research audit

5 linked publications. Exposure and population details describe the anchor studies; combined findings link each statement to its source. Quantitative results remain study-specific, with unavailable estimates stated explicitly. Sensory indicators also include exposure routes described in the additional research, with their own citations. Multiple senses in a setting do not establish a separate benefit from each sense.

Anchor studies

Direct experimentalLimited · atlas editorial assessment
Method
Blinded, balanced repeated chamber exposures; mixed ANOVA with Tukey HSD comparisons; cognitive tasks and self-ratings
Participants / setting
25 Danish students (10 men, 15 women), mean age 23 (SD 2), each completing five 255-minute exposures.
Study focus
Separates added pure CO₂ from accumulated occupant bioeffluents.
Finding used
Pure CO₂ showed no significant cognitive or symptom effects. Bioeffluent effects were mixed: slower addition and fewer correct links, but faster redirection in selected contrasts. Authors explicitly describe the analysis as exploratory.
Architectural relevance
Distinguish ventilation indicators from causal exposure claims; evaluate mixtures and relevant tasks.
Study-specific quantitative result
CO₂ & occupant bioeffluents: Cognitive-task performance and symptoms under CO₂ and human bioeffluent exposures Pure CO₂ addition versus reduced-ventilation human bioeffluents at comparable CO₂ concentrations 25 Danish students (10 men, 15 women), mean age 23 (SD 2), each completing five 255-minute exposures. Five 255-minute chamber exposures; approximately 500 ppm baseline, 1,000 or 3,000 ppm from pure CO₂ addition or reduced ventilation. Across conditions, addition speed differed (p=.023), as did addition errors (p=.049), redirection reaction time (p=.015), and correct Tsai–Partington links (p<.001). Bioeffluents at M3000 slowed addition versus B500, but redirection was faster versus P1000; correct links were lower at M1000 and M3000 versus B500. No pairwise addition-error contrast passed Tukey testing. Pure-CO₂ conditions showed no significant cognitive or symptom effects. Uncertainty: Omnibus p-values describe across-condition tests, not effect magnitudes or every pairwise contrast. Figure 6 supplies graphical means and 95% CIs; exact numeric limits remain unextracted because supplemental Tables S3–S5 returned 403. A nonsignificant pure-CO₂ result does not establish zero effect. Satish 2012 reports contrary task-specific findings. Analysis: exploratory CO₂ can mark inadequate ventilation and co-occurring human emissions. Do not attribute every association to CO₂ itself or claim an established cerebral oxygen-depletion mechanism at these concentrations. Material checked: Full accepted manuscript Methods, Results and Figure 6 reviewed. Authors explicitly call this analysis exploratory; this designation is not inferred from the number of outcomes.
Interpretation limits
Task-specific, exploratory results; not every bioeffluent task worsened. Graphical 95% CIs are reported; exact supplementary values remain inaccessible.
Verification status
Full paper · relevant sections checked
Sections checked
Accepted manuscript Methods; Statistical Analysis; Results; Figure 6 and exploratory-analysis statement
Unresolved / verification limits
Exact task means/contrasts and numeric confidence bounds: main Figure 6 gives graphical least-squares means and 95% CIs, but supporting Tables S3–S5 could not be downloaded (Wiley supplement URL and downloadSupplement endpoint both HTTP 403). No precise graph digitization performed.
Last checked 2026-10-10Publication status Peer-reviewedPrimary material · verification recordResearch audit / material checked Full accepted manuscript Methods, Results and Figure 6 reviewed. Authors explicitly call this analysis exploratory; this designation is not inferred from the number of outcomes. · Full-text methods and results checked
Direct experimentalLimited · atlas editorial assessment
Method
Blinded chamber experiment · computerized decision simulation
Participants / setting
22 participants, three 2.5-hour sessions in one day
Study focus
Tests ultrapure added CO₂ with ventilation and temperature held constant.
Finding used
Several decision scales declined at 1,000 and 2,500 ppm versus 600 ppm, while focused activity increased at 2,500 ppm.
Architectural relevance
Distinguish ventilation indicators from causal exposure claims; evaluate mixtures and relevant tasks.
Interpretation limits
Small sample and specific decision instrument; later experiments are inconsistent.
Verification status
Full paper · relevant sections checked
Sections checked
Methods: exposure protocol and study participants · Results: decision-making scales · Discussion: synthesis and interpretation
Last checked 2026-10-10Publication status Peer-reviewedPrimary material · verification recordResearch audit / material checked Relevant full-text body sections checked · Full body confirms the small blinded chamber study and separate decision-scale results: several scores declined, focused activity increased, and information search did not differ. This is evidence about a particular simulation and short exposure, not a universal CO₂ threshold for cognition.

Supporting and contrasting research

Direct experimentalModerate · atlas editorial assessment
Method
Blinded controlled office exposures · decision-making simulation
Participants / setting
24 participants, six full workdays
Study focus
Varies office VOCs, outdoor-air supply and added CO₂ across workdays.
Finding used
Decision scores were higher under low-VOC and enhanced-ventilation conditions.
Architectural relevance
Distinguish ventilation indicators from causal exposure claims; evaluate mixtures and relevant tasks.
Interpretation limits
Small sample and one decision simulation; large relative test-score differences are not equivalent to productivity gains.
Verification status
Full paper · relevant sections checked
Sections checked
Statistical Analyses; Results; Table 5
Last checked 2026-10-10Publication status Peer-reviewedPrimary material · verification recordResearch audit / material checked Targeted full-text verification; not a formal risk-of-bias assessment. · Full-text Methods and Results checked
Indirect · evidence synthesisLimited for isolated causal effects
Method
Literature review; 31 health/productivity studies plus environmental surveys
Participants / setting
Office workers across reviewed studies
Study focus
Reviews office air pollution, thermal, lighting and acoustic conditions and occupant outcomes.
Finding used
Environmental quality was associated with symptom complaints and work-related outcomes across heterogeneous studies.
Architectural relevance
Provides wider indoor-air-quality context for assessing ventilation and exposure mixtures; it does not resolve the conflicting pure-CO₂ experiments.
Interpretation limits
Exposure mixtures and mixed designs prevent a single causal pollutant or productivity effect from being inferred.
Verification status
Full paper · relevant sections checked
Sections checked
2. Method · 3.4.2 Effects of occupational exposure to inorganic air pollutants · 6.2 Effects of acoustical conditions on workers · 7. Conclusions and future trends
Last checked 2026-10-10Publication status Peer-reviewedPrimary material · verification recordResearch audit / material checked Relevant full-text body sections checked · Public author-uploaded body confirms the mixed literature on office environmental exposures and health/productivity outcomes, including inconsistent CO₂ results. The authors call for objective outcomes and investigation of interacting environmental factors. Findings do not justify single-pollutant causal or universal productivity claims.
Direct neural experiment; indirect architectural transferLimited for architectural benefit claims · atlas editorial assessment
Method
Event-related fMRI · odor delivery and conditioning
Participants / setting
17 healthy adults recruited, 15 analyzed; ages 18–31.
Study focus
Examines odors varying in valence during a conditioning paradigm.
Finding used
Responses differed across piriform and orbitofrontal subregions; amygdala responses occurred across odor valences.
Architectural relevance
Accompanying bioeffluent odors only.
Interpretation limits
Different odors and task from the atlas anchor. Results do not establish benefits of scenting a room; the atlas cannot reproduce functional subregional boundaries.
Verification status
Partial check · primary body excerpts
Sections checked
Prior indexed PMC Methods/Results · Current PubMed metadata and abstract
Unresolved / verification limits
Complete Methods, statistical tables and exclusions remain outside the verified material.
Last checked 2026-10-10Publication status Peer-reviewedPrimary material · verification recordResearch audit / material checked Previously checked primary body excerpts, with metadata rechecked; complete full paper not newly inspected. · The source supports differentiated olfactory responses. Complete body retrieval was blocked at PMC and the Max Planck manuscript repository in this pass; retain the narrower prior extraction.

Why this evidence grade: Small controlled studies provide conflicting evidence: a 22-person simulation study found lower decision-making scores, while a 25-person experiment found no significant effects of added pure CO₂ but effects under reduced-ventilation bioeffluent exposure. Exposure mixtures and test differences justify retaining a limited grade. Atlas editorial assessment; not formal GRADE.