NeuroarchitectureDLA Visual AtlasVersion 1.0
DLA research workspace

Evidence Atlas

Explore the relationships between architecture, experience and the body.

Body & evidence

Direct experimentalLimited evidence
About these labels

Relationship describes how the study connects to this architectural exposure. Confidence describes the support and limits for using that finding in design. A close match to a building or population does not by itself make the evidence strong.

Relationship

Direct experimentalSelected
The study manipulated an environmental feature or its representation. The finding applies to the tested exposure and participants.
Indirect
The architectural relationship uses an observational study, evidence synthesis or a transfer from another exposure or setting.
Theoretical inference
This relationship is a design or mechanistic hypothesis; the anchor does not establish a measured human benefit.

Confidence

Moderate evidence
A credible result within the tested conditions, with limits when transferred to another population, exposure or building.
Limited evidenceSelected
Confidence is restricted by factors such as a small sample, proxy measures, confounding or an uncertain transfer to architectural design.
Hypothesis
The proposed architectural relationship has no established measured human outcome in the anchor evidence.

These are atlas editorial assessments, not a formal GRADE assessment. A direct experiment can still provide limited evidence, and design recommendations remain interpretations of the findings.

Light flicker / temporal modulation

Study exposure

Constant light versus 100 and 500 Hz modulation at 100% depth and 50% duty cycle

Eyes · temporal light response

Measured with

Eye tracking

Research finding

Pupil size increased at 100 Hz versus constant light.

Observation details & sources
Exposure

Modulated versus constant light

Measurement

Eye tracking

Finding

Pupil size increased at 100 Hz versus constant light.

Interpretation

Frequency, modulation depth and duty cycle all define exposure.

Light · documented exposure

Time-varying light reaches the retina. Temporal modulation can affect visual processing even when obvious flicker is not consciously noticed.

Design implication

Specify and measure stable luminaire output across dimming settings; assess symptoms and task performance.

Design proposal · Theoretical inferenceExplore design approaches →
Interpretation & limits

Findings are waveform-specific. The anchor’s main table and appendix disagree on the overall accuracy-contrast statistics. A 13-week moderate-modulation office study found no increased complaints.

Light flicker / temporal modulation

Environmental comfort

Loading body model…

  • Light
Spatial context

Related regions

Direct experimentalLimited evidence
About these labels

Relationship describes how the study connects to this architectural exposure. Confidence describes the support and limits for using that finding in design. A close match to a building or population does not by itself make the evidence strong.

Relationship

Direct experimentalSelected
The study manipulated an environmental feature or its representation. The finding applies to the tested exposure and participants.
Indirect
The architectural relationship uses an observational study, evidence synthesis or a transfer from another exposure or setting.
Theoretical inference
This relationship is a design or mechanistic hypothesis; the anchor does not establish a measured human benefit.

Confidence

Moderate evidence
A credible result within the tested conditions, with limits when transferred to another population, exposure or building.
Limited evidenceSelected
Confidence is restricted by factors such as a small sample, proxy measures, confounding or an uncertain transfer to architectural design.
Hypothesis
The proposed architectural relationship has no established measured human outcome in the anchor evidence.

These are atlas editorial assessments, not a formal GRADE assessment. A direct experiment can still provide limited evidence, and design recommendations remain interpretations of the findings.

Select a region for its finding and supporting source.

Explore design approaches →
Visual cortex / occipital lobeSeparate fMRI study · indirect architectural linkBroad anatomical territory

Separate 7T fMRI found occipital contrasts at 50 and 100 Hz square modulation; 700 Hz was null. This broad reference is not the statistical map.

Several anatomical parcels illustrate this broad system. Their combined extent is not a validated functional network.

Light flicker / temporal modulation

Environmental comfort

Loading anatomical surface…
  • Light
Anterior = front · posterior = back
Peer-reviewed sources & research auditStudy details · 4 papersOpen auditClose audit

Peer-reviewed sources & research audit

Sensory accessibility

4 linked publications. Exposure and population details describe the anchor study; combined findings link each statement to its source. Quantitative results remain study-specific, with unavailable estimates stated explicitly. Sensory indicators also include exposure routes described in the additional research, with their own citations. Multiple senses in a setting do not establish a separate benefit from each sense.

Anchor study

Direct experimentalLimited · atlas editorial assessment
Method
Repeated no-TLM, 100-Hz and 500-Hz conditions; 100% rectangular modulation and 50% duty cycle for modulated conditions. Behavioral Stroop testing, eye measurements and EEG/ERP with modeled source estimates. Analyses used planned contrasts and outcome-specific outlier exclusion (z-score >3).
Participants / setting
48 healthy undergraduates completed; 34 retained for the study (27 women, 7 men; mean age 19.7 years, range 18–26). Outcome-specific outlier removal left 32 for overall Stroop accuracy and 33 for overall reaction time. 14 excluded: 5 technical malfunctions, 1 non-adherence to task instructions, 2 failures of vision requirements, 6 excessive EEG artifacts.
Study focus
Compares constant light, 100 Hz and 500 Hz modulation.
Finding used
At 100 Hz, pupil measures and ERP source strength increased relative to constant light; anxiety did not differ. Stroop accuracy interference was smaller at 500 than 100 Hz, while reaction-time contrasts were nonsignificant.
Architectural relevance
Measure light-output stability and dimmer behavior; compare comfort and performance.
Study-specific quantitative result
Light flicker / temporal modulation: Stroop accuracy interference (incongruent minus congruent percentage correct) Planned comparison of 100-Hz versus 500-Hz temporal light modulation 48 completed; 34 retained (27 women, 7 men; mean age 19.7, range 18–26). Accuracy analysis retained 32 after outcome-specific outlier exclusion. Repeated no-TLM, 100-Hz and 500-Hz light conditions; modulated conditions used rectangular 100% modulation at 50% duty cycle. Overall accuracy interference was -2.96 percentage points (SD 2.18) at 100 Hz versus -1.75 (SD 2.04) at 500 Hz; F(1,31)=7.70, p=.01, partial eta-squared=.20, Cohen's d=.50. Reaction-time contrasts were nonsignificant. Uncertainty: No CI is reported. Main Table 1 gives F(1,31)=7.70, partial eta²=.20, d=.50; Appendix D3 gives F(1,31)=9.57, eta²=.24, d=.56 for the same overall 100-versus-500 Hz accuracy comparison. This internal discrepancy is unresolved; the displayed estimate follows the main table. Analysis: Outcome hierarchy not specified in the material checked. A planned, task-specific laboratory contrast; it does not establish a general cognitive benefit of 500-Hz lighting or define a universally safe flicker threshold. Material checked: Full paper: Methods; Results 3.1.2; Table 1; Appendix D2–D5. Two comparisons are called planned, but the manuscript declares neither outcome hierarchy nor preregistration.
Interpretation limits
Specific 100% modulation, 50% duty-cycle stimuli; source estimates cannot provide exact personal anatomy. Findings do not recommend deliberate flicker.
Verification status
Full paper · relevant sections checked
Sections checked
Methods; Results 3.1.2; Table 1; Appendix D2–D5
Unresolved / verification limits
Internal inconsistency between main Table 1 and Appendix D3 for overall accuracy inferential statistics; raw-data reanalysis or author correction would be needed to resolve it.
Last checked 2026-10-10Publication status Peer-reviewedPrimary material checkedResearch audit / material checked Targeted full-text verification; not a formal risk-of-bias assessment. · Full-text Methods and Results checked

Supporting and contrasting research

Fluorescent lighting, headaches and eyestrain

Wilkins et al. (1989) · Lighting Research & Technology

Direct experimentalLimited · atlas editorial assessment
Method
Double-blind crossover · weekly symptom reports
Participants / setting
178 initially agreed; 159 regular autumn respondents; attrition and mixed fixtures reduced outcome samples. Paired headache analysis used 42; Table 2 paired eyestrain rows contain 40.
Study focus
Compares fluorescent ballast conditions in occupied offices.
Finding used
Headache frequency generally favored high-frequency lighting, but the aggregate paired headache result was p=.059 one-tailed; paired eyestrain was p=.037 one-tailed. Between-group significance differed before/after changeover.
Architectural relevance
Consider temporal modulation in addition to brightness and color temperature.
Interpretation limits
Historical fluorescent circuits, attrition and differing outcome samples; top-floor offices were excluded from randomized changes. Abstract halving should not imply all paired tests significant. Tables give SD, not effect CIs; outcome hierarchy not declared.
Verification status
Full paper · relevant sections checked
Sections checked
Full scanned Methods2.1–2.6; Results3.1–3.6; Tables1–2 visually inspected
Last checked 2026-10-10Publication status Peer-reviewedPrimary material · verification recordResearch audit / material checked Targeted source verification, not a formal risk-of-bias assessment. · Full-paper Methods and Results checked
Direct experimentalLimited · atlas editorial assessment
Method
Field intervention · repeated daily questionnaires
Participants / setting
46 lighting-company employees exposed; questionnaire completion varied
Study focus
Compares two LED modulation settings over 13 weeks.
Finding used
The higher-modulation setting did not significantly increase the measured health or wellbeing complaints.
Architectural relevance
Keep exposure level and contrary findings visible in lighting specifications.
Interpretation limits
Industry setting and moderate modulation; null findings do not generalize to all waveforms or sensitive populations.
Verification status
Full paper · relevant sections checked
Sections checked
Publisher Methods and Discussion reviewed in prior audit; not unnecessarily reread
Last checked 2026-10-10Publication status Peer-reviewedResearch audit / material checked Targeted source verification, not a formal risk-of-bias assessment. · Prior full-text review retained
Direct experimentalLimited · architectural transfer
Method
7T fMRI · controlled LED modulation · flicker-threshold test
Participants / setting
30 enrolled; 25 analyzed (13 women), ages 20–34, mean 24.2 (SD 4.8).
Study focus
Compares constant light with controlled modulation frequencies and waveforms.
Finding used
Occipital activation appeared at 50/100 Hz square modulation; 300 Hz yielded one cluster and 700 Hz none. Some conditions also caused deactivation.
Architectural relevance
Supplemental occipital localization; distinct from the EEG anchor.
Interpretation limits
Specific bright-screen exposure; responses do not establish harm, benefit or a universal threshold.
Verification status
Partial check · primary body excerpts
Sections checked
Publisher-indexed §2.1 participants · Publisher-indexed §3 Results
Unresolved / verification limits
Complete inferential tables, preprocessing details and supplementary analyses remain unverified. No health-risk threshold is inferred from BOLD response.
Last checked 2026-10-10Publication status Peer-reviewedPrimary material · verification recordResearch audit / material checked Primary publisher-indexed body excerpts checked; complete full text and supplements not accessible in this pass. · Indexed Methods resolve the sample: 30 enrolled, 25 analyzed after three vision, one scheduling and one MRI-artifact exclusions. Indexed Results support frequency-dependent BOLD responses; the complete statistical tables and supplements were not inspected.

Why this evidence grade: A laboratory study retained 34 of 48 participants and used outcome-specific exclusions, leaving 32 for accuracy. A planned 100-versus-500-Hz accuracy contrast coexists with null reaction-time results and multiple EEG outcomes; older symptom findings and null LED field findings involve different exposures. Atlas editorial assessment; not formal GRADE.