Explore the relationships between architecture, experience and the body.

Body & evidence

Direct experimentalLimited evidence
About these labels

Relationship describes how the study connects to this architectural exposure. Confidence describes the support and limits for using that finding in design. A close match to a building or population does not by itself make the evidence strong.

Relationship

Direct experimentalSelected
The study manipulated an environmental feature or its representation. The finding applies to the tested exposure and participants.
Indirect
The architectural relationship uses an observational study, evidence synthesis or a transfer from another exposure or setting.
Theoretical inference
This relationship is a design or mechanistic hypothesis; the anchor does not establish a measured human benefit.

Confidence

Moderate evidence
A credible result within the tested conditions, with limits when transferred to another population, exposure or building.
Limited evidenceSelected
Confidence is restricted by factors such as a small sample, proxy measures, confounding or an uncertain transfer to architectural design.
Hypothesis
The proposed architectural relationship has no established measured human outcome in the anchor evidence.

These are atlas editorial assessments, not a formal GRADE assessment. A direct experiment can still provide limited evidence, and design recommendations remain interpretations of the findings.

Glare & luminance contrast

Study exposure

Lighting conditions manipulated to produce different levels of discomfort glare

Eyes · glare response

Measured with

Electro-oculography in 20 adults; pupil tracking only in 10 younger adults.

Research finding

Movement speed and pupil constriction tracked discomfort.

Observation details & sources
Exposure

Different glare conditions

Measurement

Electro-oculography in 20 adults; pupil tracking only in 10 younger adults.

Finding

Movement speed and pupil constriction tracked discomfort.

Interpretation

Retinal adaptation also affects these measures; include subjective reports.

Sight · documented exposure

Brightness distribution and viewing direction change the retinal exposure; the cited studies recorded discomfort ratings and ocular responses.

Design implication

Compare shading, luminaire shielding and workstation direction using luminance maps and occupant reports.

Design proposal · Theoretical inferenceExplore design approaches →
Interpretation & limits

Small controlled samples; pupil size is light-sensitive and cannot independently diagnose strain or stress.

Glare & luminance contrast

Environmental comfort

Loading body model…

  • Sight
Spatial context

Related regions

Direct experimentalLimited evidence
About these labels

Relationship describes how the study connects to this architectural exposure. Confidence describes the support and limits for using that finding in design. A close match to a building or population does not by itself make the evidence strong.

Relationship

Direct experimentalSelected
The study manipulated an environmental feature or its representation. The finding applies to the tested exposure and participants.
Indirect
The architectural relationship uses an observational study, evidence synthesis or a transfer from another exposure or setting.
Theoretical inference
This relationship is a design or mechanistic hypothesis; the anchor does not establish a measured human benefit.

Confidence

Moderate evidence
A credible result within the tested conditions, with limits when transferred to another population, exposure or building.
Limited evidenceSelected
Confidence is restricted by factors such as a small sample, proxy measures, confounding or an uncertain transfer to architectural design.
Hypothesis
The proposed architectural relationship has no established measured human outcome in the anchor evidence.

These are atlas editorial assessments, not a formal GRADE assessment. A direct experiment can still provide limited evidence, and design recommendations remain interpretations of the findings.

Select a region for its finding and supporting source.

Explore design approaches →
Visual cortex / occipital lobeAnatomical pathway · indirectBroad anatomical territory

Separate luminance fMRI supplies visual-processing context. It did not test the anchor's architectural glare or discomfort mechanism.

Several anatomical parcels illustrate this broad system. Their combined extent is not a validated functional network.

Glare & luminance contrast

Environmental comfort

Loading anatomical surface…
  • Sight
Anterior = front · posterior = back
Peer-reviewed sources & research auditStudy details · 4 papersOpen auditClose audit

Peer-reviewed sources & research audit

Sensory accessibility

4 linked publications. Exposure and population details describe the anchor study; combined findings link each statement to its source. Quantitative results remain study-specific, with unavailable estimates stated explicitly. Sensory indicators also include exposure routes described in the additional research, with their own citations. Multiple senses in a setting do not establish a separate benefit from each sense.

Anchor study

Eye movement and pupil size constriction under discomfort glare

Lin et al. (2015) · Investigative Ophthalmology & Visual Science

Direct experimentalLimited · atlas editorial assessment
Method
Controlled visual exposure · EOG · eye tracking · de Boer ratings
Participants / setting
20 Asian participants for discomfort/EOG: 10 young (24.5±1.6 years) and 10 older (60.8±3.9 years). Only the 10 young participants wore the pupil-tracking glasses.
Study focus
Manipulates glare while recording eye responses and discomfort.
Finding used
More severe glare was associated with faster eye movement and stronger pupil constriction.
Architectural relevance
Assess view-direction luminance and occupant discomfort when designing shading.
Study-specific quantitative result
Glare & luminance contrast: Discomfort-glare ratings associated with eye movements and pupil constriction Physiological responses across glare-rating levels and age groups 20 Asian participants for discomfort/EOG: 10 young (24.5±1.6 years) and 10 older (60.8±3.9 years). Only the 10 young participants wore the pupil-tracking glasses. Controlled laboratory glare conditions; eye movement by EOG and pupil measurement by eye tracker. Reported fits relating discomfort ratings to eye-movement measures had R²>.94 (p<.001); the pupil-constriction fit had R²=.38 (p<.001). Uncertainty: No CI for the reported fitted associations is given in the full paper. Eye-movement and pupil fits use different participant coverage; R² is model fit, not percent of people affected. Analysis: Outcome hierarchy not specified in the material checked. These are candidate correlates of glare discomfort, not universal stress biomarkers or proof of a disease mechanism. Material checked: Full paper: Methods/Participants; Results and Analysis; Tables 2–4; Figures 5–6. Outcome hierarchy not declared in reviewed Methods/analysis; no preregistration inferred.
Interpretation limits
Small sample; ocular responses also reflect light adaptation and are not unique stress markers.
Verification status
Full paper · relevant sections checked
Sections checked
Methods/Participants; Results and Analysis; Tables 2–4; Figures 5–6
Last checked 2026-10-10Publication status Peer-reviewedPrimary material · verification recordResearch audit / material checked Targeted full-text verification; not a formal risk-of-bias assessment. · Full-text Methods and Results checked

Supporting and contrasting research

Direct experimentalLimited · atlas editorial assessment
Method
Lighting experiment · eye tracking · photometry · ratings · visual performance
Participants / setting
98 recruited (48 men, 50 women), ages 18–36, mean 23.56 (SD 4.81); low 35/medium 30/high 33. Physiological outcome Ns vary: fixation 96, blink/pupil 95.
Study focus
Tests ocular and performance measures across glare conditions.
Finding used
High discomfort was associated with greater fixation rate and blink amplitude, lower blink rate and poorer visual performance. Pupil direction is reported, but its accepted-manuscript test statistics are internally inconsistent.
Architectural relevance
Combine luminance mapping, reading comfort and ocular measures.
Interpretation limits
Young native-English speakers without corrective lenses; outcome-specific data availability. Pupil statistics conflict within the accepted text. Table 2 reports SD and Figure 5 graphical 95% CIs. Outcome hierarchy not declared.
Verification status
Full paper · relevant sections checked
Sections checked
Participants2.2; analysis4.1; Results4.2–4.4; Table2
Unresolved / verification limits
Accepted manuscript pupil paragraph contradicts itself: calls F(2,92)=.63, p=.54 significant and repeats mean 2.69 for both groups, whereas Table 2 reports low 2.69/high 2.50. Exact pupil-test statistics require final-version correction; do not silently repair.
Last checked 2026-10-10Publication status Peer-reviewedPrimary material · verification recordResearch audit / material checked Targeted source verification, not a formal risk-of-bias assessment. · Full-paper Methods and Results checked
Direct experimentalModerate for glare assessment · atlas editorial assessment
Method
Test-room experiments · CCD luminance mapping · subjective glare evaluation
Participants / setting
76 participants (48 men, 28 women), ages 20–59; 22 at SBi and 54 at ISE.
Study focus
Develops a daylight-glare prediction method from luminance images and occupant responses.
Finding used
The study links luminance distribution and eye-level illuminance with reported discomfort to derive a glare metric.
Architectural relevance
Use measured or simulated luminance to test shading and workstation orientation.
Interpretation limits
Glare-prediction model development, not a stress/health trial. Participant mix differs between sites; full validation tables remain unavailable in this pass.
Verification status
Partial verification · see unresolved items
Sections checked
Publisher-indexed Methods participant passage; Fraunhofer/Aalborg repository metadata
Unresolved / verification limits
Full final paper tables/CIs and model-validation details were not re-retrieved. Publisher full/abstract endpoints currently403; Fraunhofer record has metadata only. Sample verified from indexed primary Methods excerpt, not inferred from secondary reviews.
Last checked 2026-10-10Publication status Peer-reviewedResearch audit / material checked Targeted source verification, not a formal risk-of-bias assessment. · Abstract/accessible sections checked; full paper unavailable
Direct experimentalLimited · architectural transfer
Method
fMRI · eye tracking · brightness judgments
Participants / setting
9 adults across imaging experiments, 30–36 years
Study focus
Manipulates uniform-surface luminance during fMRI.
Finding used
Early visual responses tracked retinal illumination changes; pupil dynamics mattered.
Architectural relevance
Luminance-processing context.
Interpretation limits
Small sample; no room-size, glare-discomfort or daylight intervention.
Verification status
Earlier full-text extraction retained
Last checked 2026-09-13Publication status Peer-reviewedResearch audit / material checked Targeted full-text extraction; no formal risk-of-bias assessment. · Primary full-text methods and results reviewed

Why this evidence grade: The anchor includes 20 participants for eye-movement and discomfort measurements, but only 10 younger participants for pupil measurements. These laboratory associations support studying glare discomfort; they do not validate ocular metrics as universal stress or health biomarkers. Atlas editorial assessment; not formal GRADE.