NeuroarchitectureDLA Visual AtlasVersion 1.0
DLA research workspace

Evidence Atlas

Explore the relationships between architecture, experience and the body.

Body & evidence

Direct experimentalModerate evidence
About these labels

Relationship describes how the study connects to this architectural exposure. Confidence describes the support and limits for using that finding in design. A close match to a building or population does not by itself make the evidence strong.

Relationship

Direct experimentalSelected
The study manipulated an environmental feature or its representation. The finding applies to the tested exposure and participants.
Indirect
The architectural relationship uses an observational study, evidence synthesis or a transfer from another exposure or setting.
Theoretical inference
This relationship is a design or mechanistic hypothesis; the anchor does not establish a measured human benefit.

Confidence

Moderate evidenceSelected
A credible result within the tested conditions, with limits when transferred to another population, exposure or building.
Limited evidence
Confidence is restricted by factors such as a small sample, proxy measures, confounding or an uncertain transfer to architectural design.
Hypothesis
The proposed architectural relationship has no established measured human outcome in the anchor evidence.

These are atlas editorial assessments, not a formal GRADE assessment. A direct experiment can still provide limited evidence, and design recommendations remain interpretations of the findings.

Ventilation & indoor emissions

Study exposure

Ventilation, VOC and CO₂ conditions varied across office exposures

Cognitive task performance

Measured with

Computerized response/decision tasks

Research finding

Decision-making scores were higher in low-VOC and enhanced-ventilation conditions than conventional conditions.

Observation details & sources
Exposure

Ventilation, VOC and CO₂ conditions varied across office exposures

Measurement

Computerized response/decision tasks

Finding

Decision-making scores were higher in low-VOC and enhanced-ventilation conditions than conventional conditions.

Interpretation

Behavioral outcomes do not locate a specific organ response.

Design implication

Compare ventilation and low-emission specifications using measured exposure and task outcomes.

Design proposal · Theoretical inferenceExplore design approaches →
Interpretation & limits

Small controlled sample; exposure combinations and a specific decision test limit transfer to everyday productivity.

Ventilation & indoor emissions

Environmental comfort

Loading body model…

  • Inhalation
  • Smell
Spatial context

Related regions

Direct experimentalModerate evidence
About these labels

Relationship describes how the study connects to this architectural exposure. Confidence describes the support and limits for using that finding in design. A close match to a building or population does not by itself make the evidence strong.

Relationship

Direct experimentalSelected
The study manipulated an environmental feature or its representation. The finding applies to the tested exposure and participants.
Indirect
The architectural relationship uses an observational study, evidence synthesis or a transfer from another exposure or setting.
Theoretical inference
This relationship is a design or mechanistic hypothesis; the anchor does not establish a measured human benefit.

Confidence

Moderate evidenceSelected
A credible result within the tested conditions, with limits when transferred to another population, exposure or building.
Limited evidence
Confidence is restricted by factors such as a small sample, proxy measures, confounding or an uncertain transfer to architectural design.
Hypothesis
The proposed architectural relationship has no established measured human outcome in the anchor evidence.

These are atlas editorial assessments, not a formal GRADE assessment. A direct experiment can still provide limited evidence, and design recommendations remain interpretations of the findings.

Select a region for its finding and supporting source.

Explore design approaches →
Olfactory / piriform regionAnatomical pathway · indirectApproximate location only

Odor-perception context only: the ventilation study included odor ratings. This does not localize pollutant-related cognitive effects.

No dedicated segmentation in the loaded atlas. The marker remains approximate; no exact location is claimed.

Ventilation & indoor emissions

Environmental comfort

Loading anatomical surface…
  • Inhalation
  • Smell
Anterior = front · posterior = back
Peer-reviewed sources & research auditStudy details · 5 papersOpen auditClose audit

Peer-reviewed sources & research audit

5 linked publications. Exposure and population details describe the anchor study; combined findings link each statement to its source. Quantitative results remain study-specific, with unavailable estimates stated explicitly. Sensory indicators also include exposure routes described in the additional research, with their own citations. Multiple senses in a setting do not establish a separate benefit from each sense.

Anchor study

Direct experimentalModerate · atlas editorial assessment
Method
Blinded controlled office exposures · decision-making simulation
Participants / setting
24 participants, six full workdays
Study focus
Varies office VOCs, outdoor-air supply and added CO₂ across workdays.
Finding used
Decision scores were higher under low-VOC and enhanced-ventilation conditions.
Architectural relevance
Compare ventilation and low-emission specifications using measured exposure and task outcomes.
Study-specific quantitative result
Ventilation & indoor emissions: Strategic Management Simulation cognitive scores Low-VOC Green and low-VOC/high-ventilation Green+ conditions versus Conventional conditions 24 participants in a blinded repeated-exposure experiment. Six full workdays (09:00–17:00) in a controlled office under differing ventilation, VOC and CO₂ conditions. Average SMS score ratio versus Conventional: Green 1.61 (95% CI 1.51–1.71); Green+ Day 1 1.99 (1.89–2.09); Green+ Day 6 2.03 (1.93–2.13); all p<.0001. The paper summarizes the two Green+ days as 101% higher. Uncertainty: Table 5 provides model-based CIs separately for Green+ days; it does not provide one pooled CI for the 101% summary. Simulation-score ratios are not percentage gains in productivity. Analysis: Outcome hierarchy not specified in the material checked. The condition comparison bundles aspects of air quality. It does not demonstrate a 101% productivity gain, an IQ gain, or that ordinary indoor CO₂ acts through oxygen deprivation. Material checked: Full paper: Statistical Analyses; Results; Table 5. Outcome hierarchy not declared in reviewed Methods/analysis; no preregistration inferred.
Interpretation limits
Small sample and one decision simulation; large relative test-score differences are not equivalent to productivity gains.
Verification status
Full paper · relevant sections checked
Sections checked
Statistical Analyses; Results; Table 5
Last checked 2026-10-10Publication status Peer-reviewedPrimary material · verification recordResearch audit / material checked Targeted full-text verification; not a formal risk-of-bias assessment. · Full-text Methods and Results checked

Supporting and contrasting research

Direct experimentalModerate for tested conditions · atlas editorial assessment
Method
Blinded repeated exposure · ratings · simulated office tasks
Participants / setting
30 women recruited; 29 completed 3 and 30 L/s-person conditions and 27 completed 10 L/s-person; three 4.6-hour sessions.
Study focus
Tests outdoor-air supply while other conditions remain stable.
Finding used
Typing/addition/proofreading ANOVAs were nonsignificant. A subsequent log-linear combined speed/accuracy trend reached p<.03 for typing. Creative-thinking scores improved from 3 to 10 L/s-person in one-tailed pairwise tests (p<.025; originality-weighted p<.046).
Architectural relevance
Pair outdoor-air changes with measured pollutants and relevant task outcomes.
Interpretation limits
Several analytic approaches, short tasks and narrow sample. The across-task 1.4–1.7% per ventilation doubling is a modeled trend, not significant improvement on every task. Outcome hierarchy not declared; reported figures do not supply exact contrast CIs.
Verification status
Full paper · relevant sections checked
Sections checked
Subjects; statistical analyses; Results pp230–232; Figure6
Last checked 2026-10-10Publication status Peer-reviewedPrimary material · verification recordResearch audit / material checked Targeted source verification, not a formal risk-of-bias assessment. · Full-paper Methods and Results checked
Indirect · evidence synthesisLimited for isolated causal effects
Method
Literature review; 31 health/productivity studies plus environmental surveys
Participants / setting
Office workers across reviewed studies
Study focus
Reviews office air pollution, thermal, lighting and acoustic conditions and occupant outcomes.
Finding used
Environmental quality was associated with symptom complaints and work-related outcomes across heterogeneous studies.
Architectural relevance
Provides wider indoor-air-quality context for assessing ventilation and exposure mixtures; it does not resolve the conflicting pure-CO₂ experiments.
Interpretation limits
Exposure mixtures and mixed designs prevent a single causal pollutant or productivity effect from being inferred.
Verification status
Full paper · relevant sections checked
Sections checked
2. Method · 3.4.2 Effects of occupational exposure to inorganic air pollutants · 6.2 Effects of acoustical conditions on workers · 7. Conclusions and future trends
Last checked 2026-10-10Publication status Peer-reviewedPrimary material · verification recordResearch audit / material checked Relevant full-text body sections checked · Public author-uploaded body confirms the mixed literature on office environmental exposures and health/productivity outcomes, including inconsistent CO₂ results. The authors call for objective outcomes and investigation of interacting environmental factors. Findings do not justify single-pollutant causal or universal productivity claims.
IndirectLimited for single-feature causal claims · atlas editorial assessment
Method
Observational classroom assessments and two-level pupil/classroom modeling of annual reading, writing and maths progress.
Participants / setting
4,924 pupils initially sampled in 203 classrooms/30 schools; final analysis: 3,766 pupils, 153 classrooms, 27 English schools.
Study focus
Relates classroom conditions to pupils’ academic progress.
Finding used
Seven environmental parameters produced a modeled classroom-effect range of 7.93 progress points, 16% of the observed 50-point pupil-progress range.
Architectural relevance
Assess actual air quality rather than infer it from opening size.
Interpretation limits
The 16% headline is a range-based model summary, not a causal improvement or 16% R². Overall model R² was 58%; teaching and environmental features covary.
Verification status
Full paper · relevant sections checked
Sections checked
§3 data collection/statistics · §4 Results, especially p.126 · §6 Conclusion
Unresolved / verification limits
No single-feature causal estimate or adult-learning transfer established.
Last checked 2026-10-10Publication status Peer-reviewedPrimary material · verification recordResearch audit / material checked Primary material inspected: §3 data collection/statistics; §4 Results, especially p.126; §6 Conclusion. · Verified 10 October 2026; full-text.
Direct neural experiment; indirect architectural transferLimited for architectural benefit claims · atlas editorial assessment
Method
Event-related fMRI · odor delivery and conditioning
Participants / setting
17 healthy adults recruited, 15 analyzed; ages 18–31.
Study focus
Examines odors varying in valence during a conditioning paradigm.
Finding used
Responses differed across piriform and orbitofrontal subregions; amygdala responses occurred across odor valences.
Architectural relevance
Odor-perception pathway context.
Interpretation limits
Different odors and task from the atlas anchor. Results do not establish benefits of scenting a room; the atlas cannot reproduce functional subregional boundaries.
Verification status
Partial check · primary body excerpts
Sections checked
Prior indexed PMC Methods/Results · Current PubMed metadata and abstract
Unresolved / verification limits
Complete Methods, statistical tables and exclusions remain outside the verified material.
Last checked 2026-10-10Publication status Peer-reviewedPrimary material · verification recordResearch audit / material checked Previously checked primary body excerpts, with metadata rechecked; complete full paper not newly inspected. · The source supports differentiated olfactory responses. Complete body retrieval was blocked at PMC and the Max Planck manuscript repository in this pass; retain the narrower prior extraction.

Why this evidence grade: A blinded controlled experiment in 24 participants across six workdays supports differences on a decision-making simulation under specified ventilation, VOC and CO₂ conditions. Supporting experiments are task-dependent; the results do not measure real-world productivity or isolate a universal biological mechanism. Atlas editorial assessment; not formal GRADE.